Yarmouth is the World Leader in fugitive emission testing. Our lab can perform all industry standards using methane or helium, including, but not limited to ISO 15848, API 622, ChevronTexaco, TA-Luft -VDI 2440, ANSI/FCI 91-1, ANSI/ISA S93 and Lion Oil.
Fire Testing
High temperature testing with flame temperatures up to 1800 deg. F and metal temperatures over 1400 deg. F can be achieved in our fire test oven.Testing standards include, but are not limited to, American Petroleum Institute (API), British Standards (BS) as well as Major Oil Company custom standards.
Cryogenic Testing
Cryogenic testing down to temperatures of -196C can be performed to valves up to 24 inch. BS6364 Part 2 is a common test standard. Cryogenic testing is often performed to prove valve designs for use in LNG plants.
Flow Testing
Our 4 inch flow loop can accurately test 3 inch reduced flow or 2 inch full port valves for Cv measurements per ANSI/ISA-S75.02-1996. The loop uses the water weight method for accuracies less than 1 GPM.
The loop can also be used for cycle testing valves with water up to 500 psig.
Performance Testing
Some recent tests include:
ISO 15500-4 test for compressed natural gas has been performed.
Helium leakage testing by vacuum method down to 10-10 mbar-l/sec or sniffing method to 10-7mbar-l/sec.
API 19.3, Part D - Fugitive Emission Testing of deck seams for oil/gas storage tanks.